Tender Detail

Buyer/Seller : Can be viewed by Subscribers
DID : 71262677
Requirement : Periodical Maintenance and operation of electrical and mechanical installations involving operation, repairs and maintenance, attending to complaints/faults/ breakdowns and taking rectification action, ensuring serviceability/ satisfactory working condition of the systems, carrying-out preventive maintenance, maintenance of records/ documents etc under this contract for shift duty for all 7 days on all working days including saturdays, Sundays and holidays as per tender specifications, terms & conditions by providing/engaging of electrician & Helper., Shift Purpose-, Electrician (Skilled)- 03 No. per day for shift duty for all 7 days in a week., Helper (Un-Skilled)- 03 No. per day for shift duty for all 7 days in a week.", "Periodical Maintenance and operation of electrical and mechanical installations involving operation, repairs and maintenance, attending to complaints/faults/ breakdowns and taking rectification action, ensuring serviceability/ satisfactory working condition of the systems, carrying-out preventive maintenance, maintenance of records/ documents etc under this contract for General Shift for 06 days in a week as per tender specifications, terms & conditions by providing/engaging of electrician & Helper., General Duty Purpose-, Electrician (Skilled)- 02 Nos. per day for General shift for 6 days in a week., Helper (Un-Skilled)- 02 Nos. per day for General shift for 6 days in a week.", "Monthly visit of fire technician/engineer form OEM of FDA system or from OEM authorized dealer for carrying out healthiness check of FDA system, attending faults, carrying out preventive maintenance i/c cleaning etc. as required to Fire main panel and repeater panels, detectors , Response indicators , MCP of the FDA system etc. Making replacement of the spare parts/accessories etc. if required for healthiness of the FDA system and submission of service report to EIC. Charges against labour & tools etc. required for attending faults, preventive maintenance, servicing, replacement/installations of spare parts and accessories are included in the item., (All spare parts/accessories required for healthiness of FDA system shall be provided by AAI i.e paid to the agency against supply of materials as in extra item on market rate on submission of original invoice and supporting documents/price list of OEM)., Inventory of FDA System-, Main Control Panel & Microprocessor based Analog Addressable - 01 No., Addressable Multi Detector - 60 Nos, Addressable Heat Detector - 4 Nos, RI - 39 Nos, MCP - 3 Nos, Addressabel Hooter- 4 Nos, Fault Isolator- 4 Nos", "Maintenance & up-keeping of Fire Extinguishers, Fire suppression system and Fire fighting system installed at Shravasti Airport inclusive of periodical checking/ testing, servicing, maintaining records, attending break down calls of all Fire Extinguishers, hydrant valves, hoze boxes, pipes, branch pipes, hose reels, hose pipes, sprinklers, NRVs, pipe lines, pressure switches, main pumps, jockey pumps, booster pump, batteries, starter panels, pressure gauges, sluice valves/gate valve etc as detailed in the special conditions of the contract, particular specification etc. complete as required. , Note- This item is only service and does not cover material part. All spare parts/accessories required for healthiness of Fire Fighting system shall be provided by AAI i.e paid to the agency against supply of materials/repair of equipment as in extra item on market rate on submission of original invoice and supporting documents/price list of OEM.", Refilling of ABC type 4 Kg Fire Extinguisher, Refilling of ABC type 6 Kg Fire Extinguisher, Refilling of CO2 type 4.5 Kg Fire Extinguisher, Refilling of CO2 type 6.5 Kg Fire Extinguisher, Refilling of CO2 type 9 Kg Fire Extinguisher, "Servicing/maintenance etc. of existing 11 KV VCB panel ( installed in HT panel room - Panel Type-PIX-MV, Sr. No. 0221189475/01/1, Mfg Year 2019) as per OEM, recommendation by Er./Technician from OEMs or by Er./Technician of Authorized dealer of OEM. , Qty -02 Nos VCB (1 no I/C & 1 no O/G)-1 set, 1st Year, ", "Servicing/maintenance etc. of existing 11 KV VCB panel ( installed in HT panel room - Panel Type-PIX-MV, Sr. No. 0221189475/01/1, Mfg Year 2019) as per OEM, recommendation by Er./Technician from OEMs or by Er./Technician of Authorized dealer of OEM. , Qty -02 Nos VCB (1 no I/C & 1 no O/G)-1 set, 2nd Year", "Testing for healthiness and carrying out calibration of all relays installed in 11KV HT panel (1 No.- I/C & 1 No.- O/G of sub-station and submission of test report and calibration certificate as required. Details of HT panel Panel is - Type-Panel Type- PIX-MV, Sr. No. 0221189475/01/1, Mfg Year 2019) ., Note-Testing and callibrations to be done by OEMs recommended callibrated Kit, by their Er./Technician or by Er./Technician of Authorized dealer of OEM., First Year", "Testing for healthiness and carrying out calibration of all relays installed in 11KV HT panel (1 No.- I/C & 1 No.- O/G of sub-station and submission of test report and calibration certificate as required. Details of HT panel Panel is - Type- Panel Type- PIX-MV, Sr. No. 0221189475/01/1, Mfg Year 2019) ., Note- Testing and callibrations to be done by OEMs recommended callibrated Kit, by their Er./Technician or by Er./Technician of Authorized dealer of OEM., Second Year", "Servicing of ABB Make, Model- Air circuit breaker 800 A through OEM service Engineer / OEM authorised service Engineer including carrying out of following works racking out & removal of ACB from switch board, cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of ACB. Cleaning all parts with cleaning agents such as CRC 2 - 26 checking the various settings within the ACB of contacts, releases etc , checking the hardware for wear & tear, checking of termination & tightness, checking for all hardwares for its presence, replacement of spares / accessories for defective / worn out items (Supply of spares / accessories required for healthiness of ACB are in AAI scope), regreasing of the ACB parts as recommended by OEM, refixing the ACB, testing and observance for normal operation of ACB complete as required. (Service report to be submitted in OEM letterhead / OEM authorise Service Dealer letter head)., First Year", "Servicing of ABB Make, Model- Air circuit breaker 800 A through OEM service Engineer / OEM authorised service Engineer including carrying out of following works racking out & removal of ACB from switch board, cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of ACB. Cleaning all parts with cleaning agents such as CRC 2 - 26 checking the various settings within the ACB of contacts, releases etc , checking the hardware for wear & tear, checking of termination & tightness, checking for all hardwares for its presence, replacement of spares / accessories for defective / worn out items (Supply of spares / accessories required for healthiness of ACB are in AAI scope), regreasing of the ACB parts as recommended by OEM, refixing the ACB, testing and observance for normal operation of ACB complete as required. (Service report to be submitted in OEM letterhead / OEM authorise Service Dealer letter head)., Second Year", Supply of Tranformer mineral oil for top up in existing 500 KVA transformer., "BDV Testing (Pre filteration or after filteration) of transformer oil from CPRI including oil sample collection charges of CPRI team & submission of original CPRI test report., First Year ", "BDV Testing (Pre filteration or after filteration) of transformer oil from CPRI including oil sample collection charges of CPRI team & submission of original CPRI test report., Second Year ", Dehydration and filtration of transformer oil at site on the basis of the report of Pre-BDV check ., Rewinding of ceiling fan/ wall fan/ exhaust fan as per original characteristics with super enameled copper wire and E class insulation material, replacement of the worn out b
Company Industry: Air Transport

Key values

EMD : INR 211,831
Tender Estimated cost : INR 10,591,542
Closing date : 26/04/2024
Location : India-Uttar Pradesh

Tender Documents

Top